If you have been reading about chromatogram and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Updated 2026-08-01. Numbers and descriptions here follow the published literature rather than marketing material.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Routine quality control includes blanks, duplicates, spiked samples, and certified reference materials. Calibration curves are prepared with standards at several concentrations, and the detector response is checked for linearity. Carryover, column aging, mobile phase evaporation, and temperature drift can shift retention times or peak areas. Maintenance such as replacing seals, filters, and columns helps prevent failures. Records of injections, integration, and deviations support traceability. Audits may request raw data and instrument logs for each batch.
Developing an HPLC test begins with defining the analytes, matrix, and required reporting limits. Chemists select a separation mode, column chemistry, mobile phase composition, flow rate, and detection wavelength or mass transition. Experiments then adjust these variables to achieve adequate retention, resolution, and peak shape. System suitability tests confirm that the instrument and method perform consistently before sample analysis. Without suitable resolution, quantitative results may be unreliable. Preliminary runs often use scouting gradients to locate retention windows.
Validation establishes that a method is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, robustness, and stability of standards and samples. Acceptance criteria are defined in advance, and results are documented in a validation report. Regulatory guidance for pharmaceuticals, foods, and environmental testing differs, so the applicable framework must be identified. Ongoing verification uses control samples and trend charts after validation. Method transfer to another laboratory may require partial revalidation.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Most common for neutral and moderately polar analytes |
| Column particle size | 3–5 µm | Smaller particles improve resolution but raise backpressure |
| Mobile phase pH range | 2–8 | Silica-based columns may degrade outside this range |
| Typical flow rate | 1.0–2.0 mL/min | For analytical columns with 4.6 mm internal diameter |
| Common synonyms | HPLC, LC, high-pressure liquid chromatography | High-performance liquid chromatography is the standard expansion |
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Volanesorsen was approved by the European Medicines Agency (EMA) for the treatment of familial chylomicronaemia syndrome in May 2019. In January 2013 mipomersen (marketed as Kynamro) was approved by the FDA for the treatment of homozygous familial hypercholesterolemia. Inotersen received FDA approval for the treatment of hereditary transthyretin-mediated amyloidosis in October 2018. The application for inotersen was granted orphan drug designation. It was developed by Ionis Pharmaceuticals and licensed to Akcea Therapeutics. Patisiran (sold under Onpattro) was developed by Alnylam Pharmaceuticals, and also approved for use in the US and EU in 2018 with orphan drug designation. Its mechanism-of-action is the active substance of small interfering RNA (siRNA), which allows it to interfere with and block the production of transthyretin. As such, it was the first FDA-approved siRNA therapeutic.
Libraries of peptide aptamers have been used as "mutagens", in studies in which an investigator introduces a library that expresses different peptide aptamers into a cell population, selects for a desired phenotype, and identifies those aptamers that cause the phenotype. The investigator then uses those aptamers as baits, for example in yeast two-hybrid screens to identify the cellular proteins targeted by those aptamers. Such experiments identify particular proteins bound by the aptamers, and protein interactions that the aptamers disrupt, to cause the phenotype. In addition, peptide aptamers derivatized with appropriate functional moieties can cause specific post-translational modification of their target proteins, or change the subcellular localization of the targets.
Abraham White (March 8, 1908 – February 14, 1980) was a professor of biochemistry who made several important discoveries in his field during the middle of the 20th century and helped write a foundational textbook, Principles of Biochemistry, which was published in 1954. The book went through six editions before its authors retired. White was born in Cleveland, Ohio, to Morris and Lena White. His siblings were Essie and Julius ("Jay"). When he was about one year old, his family moved to Lafayette, Colorado, and then later to Denver. White earned his bachelor's and master's degrees at the University of Colorado and a Ph.D. degree in Physiological Chemistry at the University of Michigan in the laboratory of Howard B. Lewis. This was followed by a postdoctoral fellowship at the Yale School of Medicine with Hubert Bradford Vickery at the Connecticut Agricultural Experiment Station.
The polar, uncharged amino acids serine (Ser, S), threonine (Thr, T), asparagine (Asn, N) and glutamine (Gln, Q) readily form hydrogen bonds with water and other amino acids. They do not ionize in normal conditions, a prominent exception being the catalytic serine in serine proteases. This is an example of severe perturbation, and is not characteristic of serine residues in general. Threonine has two chiral centers, not only the L (2S) chiral center at the α-carbon shared by all amino acids apart from achiral glycine, but also (3R) at the β-carbon. The full stereochemical specification is (2S,3R)-L-threonine. Because of the presence of phenolic hydroxyl group with a pKa = ~10, tyrosine is best classified as a neutral polar amino acid, but with amphipathic character that makes it less polar than classical small polar amino acid residues. Nonpolar amino acid interactions are the primary driving force behind the processes that fold proteins into their functional three dimensional structures. None of these amino acids' side chains ionize easily, and therefore do not have pKas.
Affimer molecules, also known as adhiron, are small proteins that bind to target proteins with affinity in the nanomolar range. These engineered non-antibody binding proteins are designed to mimic the molecular recognition characteristics of monoclonal antibodies in different applications. These affinity reagents have been optimized to increase their stability, make them tolerant to a range of temperatures and pH, reduce their size, and to increase their expression in E.coli and mammalian cells.
Sources: en.wikipedia.org
The beta sheet (β-sheet, also β-pleated sheet) is a common motif of the regular protein secondary structure. Beta sheets consist of beta strands (β-strands) connected laterally by at least two or three backbone hydrogen bonds, forming a generally twisted, pleated sheet. A β-strand is a stretch of polypeptide chain typically 3 to 10 amino acids long with backbone in an extended conformation. The supramolecular association of β-sheets has been implicated in the formation of the fibrils and protein aggregates observed in amyloidosis, Alzheimer's disease and other proteinopathies.
VIP is highly localised in lungs (70%) and binds with alveolar type II (AT II) cells via VPAC1. The biological (vasodilator) activity of vasoactive intestinal peptide (VIP) was discovered in the lungs before the peptide was isolated and chemical identity characterized from intestine. VIP levels are also considerably high in the brain and the gut. It is localized in key sites in the lung, has potent activities on its major functions, and appears to play an important role in pulmonary physiology and disease. The principal localization of VIP-containing neurons in the tracheobronchial tree is in the smooth muscle layer, around submucosal mucous glands and in the walls of pulmonary and bronchial arteries. Immunoreactive VIP is also present in neuronal cell bodies forming microglia that provide a source of intrinsic innervation of pulmonary structures.
Chinese hamster ovary (CHO) cells are a family of immortalized cell lines derived from epithelial cells of the ovary of the Chinese hamster, often used in biological and medical research and commercially in the production of recombinant therapeutic proteins. They have found wide use in studies of genetics, toxicity screening, nutrition and gene expression, and particularly since the 1980s to express recombinant proteins. CHO cells are the most commonly used mammalian hosts for industrial production of recombinant protein therapeutics.
β-pleated sheet structures are made from extended β-strand polypeptide chains, with strands linked to their neighbours by hydrogen bonds. Due to this extended backbone conformation, β-sheets resist stretching. β-sheets in proteins may carry out low-frequency accordion-like motion as observed by the Raman spectroscopy and analyzed with the quasi-continuum model. A β-helix is formed from repeating structural units consisting of two or three short β-strands linked by short loops. These units "stack" atop one another in a helical fashion so that successive repetitions of the same strand hydrogen-bond with each other in a parallel orientation. See the β-helix article for further information. In lefthanded β-helices, the strands themselves are quite straight and untwisted; the resulting helical surfaces are nearly flat, forming a regular triangular prism shape, as shown for the 1QRE archaeal carbonic anhydrase at right. Other examples are the lipid A synthesis enzyme LpxA and insect antifreeze proteins with a regular array of Thr sidechains on one face that mimic the structure of ice.
Sources: en.wikipedia.org
The general detection scheme involves: Pneumatic nebulization of mobile phase from the analytical column forming an aerosol. Aerosol conditioning to remove large droplets. Evaporation of solvent from the droplets to form dried particles. Particle charging using an ion jet formed via corona discharge. Particle selection – an ion trap is used to excess ions and high mobility charged particles. Measurement of the aggregate charge of aerosol particles using a filter/electrometer. The CAD like other aerosol detectors, can only be used with volatile mobile phases. For an analyte to be detected it must be less volatile than the mobile phase. More detailed information on how CAD works can be found on the Charged Aerosol Detection for Liquid Chromatography Resource Center.
Some have argued that there is little evidence to indicate any benefit to using bodybuilding protein or amino acid supplements. A 2005 overview concluded that "[i]n view of the lack of compelling evidence to the contrary, no additional dietary protein is suggested for healthy adults undertaking resistance or endurance exercise". In contrast, a 2018 systematic review, meta-analysis and meta-regression concluded that, “Dietary protein supplementation significantly enhanced changes in muscle strength and size during prolonged RET in healthy adults.“ (RET is an abbreviation for resistance exercise training.) Instant breakfast Protein bar "Dietary Supplement Health and Education Act of 1994". U.S. Food and Drug Administration. 4 February 2020. Archived from the original on June 2, 2009.
pcALCL is the second most common lymphoma in the category of Cutaneous T cell lymphoma cutaneous T cell lymphomas that includes lymphomatoid papulosis, various borderline CD30-positive cutaneous T cell lymphomas, and mycosis fungoides. The median age at diagnosis for pcALC is 61 years. The disease has a male predominance and appears to be more common in Caucasian populations. Individuals with pcALCL typically present with reddish masses that initially appear in the skin or, much less frequently, the lymph nodes or various organs. These masses are nodules or tumors that are often ulcerated, greater than 2 cm in diameter, and localized to a single site. In 20% of cases, however, they occur in multiple sites. In about 10% cases followed for many years, pcALCL presenting as skin lesions progresses to extracutaneous sites, mainly to regional draining lymph nodes. Over these same long periods, however, the disease's lesions partially regress in about 50% of cases but then relapse in about 40% of cases.
Sources: en.wikipedia.org
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.
The pump maintains a steady flow rate and pressure, which keeps retention times reproducible. Pulsation or flow errors can shift peaks and distort quantitation. Modern pumps use feedback control to reduce these variations.
HPLC alone usually separates compounds but does not always identify them. Retention time matching with a known standard provides tentative identification. Coupling HPLC to mass spectrometry adds mass information that supports structural identification.
System suitability is a set of checks performed before and during a run to confirm that the instrument, column, and method work as expected. Common checks include resolution, tailing factor, theoretical plates, and relative standard deviation of replicate injections. Failure triggers troubleshooting or method adjustment.