This is a working overview of stationary phase, written for readers who want more than a one-paragraph summary but less than a textbook.
This page was last updated on 2026-03-29 and is reviewed periodically as new material appears.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Most common for neutral and moderately polar analytes |
| Column particle size | 3–5 µm | Smaller particles improve resolution but raise backpressure |
| Mobile phase pH range | 2–8 | Silica-based columns may degrade outside this range |
| Typical flow rate | 1.0–2.0 mL/min | For analytical columns with 4.6 mm internal diameter |
| Common synonyms | HPLC, LC, high-pressure liquid chromatography | High-performance liquid chromatography is the standard expansion |
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Anne Ephrussi studied biology at Harvard University in the Department of Biochemistry and Molecular Biology from where she graduated in 1979. She continued to do her PhD at the Massachusetts Institute of Technology (MIT) in the group of Susumu Tonegawa where she received her doctoral degree in 1985. Ephrussi performed postdoctoral research at Harvard University in the lab of Thomas Maniatis from 1986 to 1989 and at the Whitehead Institute for Biomedical Research with Ruth Lehmann from 1989 to 1992. Since 1992, Anne Ephrussi has been a group leader at the European Molecular Biology Laboratory (EMBL). She became the head of EMBL International Centre for Advanced Training in 2005. She served as Associate Dean (1999 - 2005) and Dean (2005 - 2008) of Graduate Studies of the EMBL International PhD program and as head of the developmental biology unit (2007-2021). She is part of numerous international Scientific Advisory Boards and Panels, organizes international conferences and scientific meetings and evaluates research grant and fellowship applications for a variety of renowned funding bodies.
Binding of a ligand to a binding site on protein often triggers a change in conformation in the protein and results in altered cellular function. Hence binding site on protein are critical parts of signal transduction pathways. Types of ligands include neurotransmitters, toxins, neuropeptides, and steroid hormones. Binding sites incur functional changes in a number of contexts, including enzyme catalysis, molecular pathway signaling, homeostatic regulation, and physiological function. Electric charge, steric shape and geometry of the site selectively allow for highly specific ligands to bind, activating a particular cascade of cellular interactions the protein is responsible for.
GOT1/cAST, the cytosolic isoenzyme derives mainly from red blood cells and heart. GOT2/mAST, the mitochondrial isoenzyme is present predominantly in liver. These isoenzymes are thought to have evolved from a common ancestral AST via gene duplication, and they share a sequence homology of approximately 45%. AST has also been found in a number of microorganisms, including E. coli, H. mediterranei, and T. thermophilus. In E. coli, the enzyme is encoded by the aspCgene and has also been shown to exhibit the activity of an aromatic-amino-acid transaminase (EC 2.6.1.57).
The Shrake–Rupley algorithm is a numerical method that draws a mesh of points equidistant from each atom of the molecule and uses the number of these points that are solvent accessible to determine the surface area. The points are drawn at a water molecule's estimated radius beyond the van der Waals radius, which is effectively similar to 'rolling a ball' along the surface. All points are checked against the surface of neighboring atoms to determine whether they are buried or accessible. The number of points accessible is multiplied by the portion of surface area each point represents to calculate the ASA. The choice of the 'probe radius' does have an effect on the observed surface area, as using a smaller probe radius detects more surface details and therefore reports a larger surface. A typical value is 1.4Å, which approximates the radius of a water molecule. Another factor that affects the results is the definition of the VDW radii of the atoms in the molecule under study. For example, the molecule may often lack hydrogen atoms, which are implicit in the structure. The hydrogen atoms may be implicitly included in the atomic radii of the 'heavy' atoms, with a measure called the 'group radii'. In addition, the number of points created on the van der Waals surface of each atom determines another aspect of discretization, where more points provide an increased level of detail.
This type of specificity is sensitive to the substrate's optical activity of orientation. Stereochemical molecules differ in the way in which they rotate plane polarized light, or orientations of linkages (see alpha, beta glycosidic linkages). Enzymes that are stereochemically specific will bind substrates with these particular properties. For example, beta-glycosidase will only react with beta-glycosidic bonds which are present in cellulose, but not present in starch and glycogen, which contain alpha-glycosidic linkages. This is relevant in how mammals are able to digest food. For instance, the enzyme Amylase is present in mammal saliva, that is stereo-specific for alpha-linkages, this is why mammals are able to efficiently use starch and glycogen as forms of energy, but not cellulose (because it is a beta-linkage). Specific equilibrium dissociation constant for formation of the enzyme-substrate complex is known as k d {\displaystyle k_{d}}
Sources: en.wikipedia.org
Biodiversity informatics deals with the collection and analysis of biodiversity data, such as taxonomic databases, or microbiome data. Examples of such analyses include phylogenetics, niche modelling, species richness mapping, DNA barcoding, or species identification tools. A growing area is also macro-ecology, i.e. the study of how biodiversity is connected to ecology and human impact, such as climate change. The enormous number of published literature makes it virtually impossible for individuals to read every paper, resulting in disjointed sub-fields of research. Literature analysis aims to employ computational and statistical linguistics to mine this growing library of text resources. For example: Abbreviation recognition – identify the long-form and abbreviation of biological terms Named-entity recognition – recognizing biological terms such as gene names Protein–protein interaction – identify which proteins interact with which proteins from text The area of research draws from statistics and computational linguistics.
Camurus is a company focused on the development of lipid lyotropic liquid crystal structures for pharmaceutical drug delivery applications. These structures are well-defined three-dimensional formations consisting of lipophilic and hydrophilic domains that can be either interconnected or isolated depending on the environmentally induced phase conditions. The unique crystalline structures offer a unique way of encapsulating and transporting Active pharmaceutical ingredients, such as small molecules, peptides and proteins through the body. The structures also allow for the use of controlled release and prevention of degradation of fragile short half live molecules, a serious issue for amino-acid based drugs.
A lot of effort has been put into controlling cell selectivity. For example, attempts have been made to modify and optimize the physicochemical parameters of the peptides to control the selectivities, including net charge, helicity, hydrophobicity per residue (H), hydrophobic moment (μ) and the angle subtended by the positively charged polar helix face (Φ). Other mechanisms like the introduction of D-amino acids and fluorinated amino acids in the hydrophobic phase are believed to break the secondary structure and thus reduce hydrophobic interaction with mammalian cells. It has also been found that Pro→Nlys substitution in Pro-containing β-turn antimicrobial peptides was a promising strategy for the design of new small bacterial cell-selective antimicrobial peptides with intracellular mechanisms of action. It has been suggested that direct attachment of magainin to the substrate surface decreased nonspecific cell binding and led to improved detection limit for bacterial cells such as Salmonella and E. coli.
The word "aptamer" is a neologism coined by Andrew D. Ellington and Jack Szostak in their first publication on the topic. They did not provide a precise definition, stating "We have termed these individual RNA sequences 'aptamers', from the Latin aptus, to fit." The word itself, however, derives from the Greek word ἅπτω, to connect or fit (as used by Homer (c. 8th century BC)) and μέρος, a component of something larger. A typical aptamer is a synthetically generated ligand exploiting the combinatorial diversity of DNA, RNA, XNA, or peptide to achieve strong, specific binding for a particular target molecule or family of target molecules. Aptamers are occasionally classified as "chemical antibodies" or "antibody mimics". However, most aptamers are small, with a molecular weight of 6-30 kDa, in contrast to the 150 kDa size of antibodies, and contain one binding site rather than the two matching antigen binding regions of a typical antibody.
Sources: en.wikipedia.org
Evolutionary developmental biology compares the developmental processes of different organisms to infer how developmental processes evolved. The field grew from 19th-century beginnings, where embryology faced a mystery: zoologists did not know how embryonic development was controlled at the molecular level. Charles Darwin noted that having similar embryos implied common ancestry, but little progress was made until the 1970s. Then, recombinant DNA technology at last brought embryology together with molecular genetics. A key early discovery was that of homeotic genes that regulate development in a wide range of eukaryotes. The field explores deep homology, the finding that dissimilar organs such as the eyes of insects, vertebrates and cephalopod molluscs, long thought to have evolved separately, are controlled by similar genes from the evo-devo gene toolkit.
PABA and its salts are used in nutritional epidemiological studies to assess the completeness of 24-hour urine collection for the determination of urinary sodium, potassium, or nitrogen levels. The potassium salt (potassium paraaminobenzoate, "aminobenzoate potassium") is used as a drug against fibrotic skin disorders, such as Peyronie's disease, under the brand name Potaba. There is a lack of strong evidence. It is believed to work by inhibiting fibroblast glycosaminoglycan secretion and stabilizing monoamine oxidase A activity. PABA is also occasionally used in pill form by sufferers of irritable bowel syndrome to treat its associated gastrointestinal symptoms. PABA derivatives have also been proposed to function as acetylcholinesterase inhibitors in diseases that cause deficient cholinergic systems, such as Alzheimer's disease.
AlphaFold 2 scoring more than 90 in CASP's global distance test (GDT) was considered a great achievement in computational biology. Nobel Prize winner and structural biologist Venki Ramakrishnan called the result "a stunning advance on the protein folding problem", adding that "It has occurred decades before many people in the field would have predicted. It will be exciting to see the many ways in which it will fundamentally change biological research." AlphaFold 2's success received wide media attention. News pieces appeared in the science press, such as Nature, Science, MIT Technology Review, and New Scientist, and the story was covered by national newspapers. A frequent theme was the ability to predict protein structures based on the constituent amino acid sequence, expected to have benefits in the life sciences—accelerating drug discovery and enabling better understanding of diseases. Some have noted that even a perfect answer to the protein prediction problem still leaves questions about the protein folding problem (and thus protein dynamics)—understanding in detail how the folding process actually occurs in nature (and how sometimes they can also misfold).
An antibody–drug conjugate consists of three components: Antibody - targets the cancer cell surface and may also elicit a therapeutic response. Payload - elicits the desired therapeutic response. Linker - attaches the payload to the antibody and should be stable in circulation only releasing the payload at the desired target. Multiple approaches to conjugation have been developed for attachment to the antibody and reviewed. DAR is the drug to antibody ratio and indicates the level of loading of the payload on the ADC.
The BtuCD and HI1470/1 are classified as large (Type II) ABC importers. The transmembrane subunit of the vitamin B12 importer, BtuCD, contains 10 TM helices and the functional unit consists of two copies each of the nucleotide binding domain (NBD) and transmembrane domain (TMD). The TMD and NBD interact with one another via the cytoplasmic loop between two TM helices and the Q loop in the ABC. In the absence of nucleotide, the two ABC domains are folded and the dimer interface is open. A comparison of the structures with (BtuCDF) and without (BtuCD) binding protein reveals that BtuCD has an opening that faces the periplasm whereas in BtuCDF, the outward-facing conformation is closed to both sides of the membrane. The structures of BtuCD and the BtuCD homolog, HI1470/1, represent two different conformational states of an ABC transporter. The predicted translocation pathway in BtuCD is open to the periplasm and closed at the cytoplasmic side of the membrane while that of HI1470/1 faces the opposite direction and open only to the cytoplasm. The difference in the structures is a 9° twist of one TM subunit relative to the other.
Sources: en.wikipedia.org
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.
The pump maintains a steady flow rate and pressure, which keeps retention times reproducible. Pulsation or flow errors can shift peaks and distort quantitation. Modern pumps use feedback control to reduce these variations.
HPLC alone usually separates compounds but does not always identify them. Retention time matching with a known standard provides tentative identification. Coupling HPLC to mass spectrometry adds mass information that supports structural identification.
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.